Angled float with valve for Kränzle buffer tank (46250)
search
  • Angled float with valve for Kränzle buffer tank (46250)
  • Angled float with valve for Kränzle buffer tank (46250)

Float with valve

46250
5.5 x 12 x 15 cm
0.1 kg
zł146.62
Tax included
Duża dostępność Duża dostępność
Delivery in 2-3 days

The float with valve for the buffer tank (angled version) is a component responsible for controlling the water level and regulating the flow of fluid in the pressure washer supply system. The angled version is used where the routing of the connection and the mounting geometry require the valve to be positioned appropriately relative to the tank.

MPN / reference: 46250

APPLICATION

The component is used in typical service and operating work:

  • control of the water level in the buffer tank,
  • stabilization of fluid supply to the feed system,
  • repair of improper filling-valve operation,
  • replacement of a worn or sticking float in the angled version,
  • rebuilding of the buffer system in machines requiring continuous and stable water supply.

SYMPTOMS - WHEN IT IS WORTH REPLACING

It is worth considering replacement of the float with valve when the following appear:

  • tank overflow or failure to shut off the water supply,
  • water level too low in the tank despite correct supply,
  • unstable system operation caused by fluctuations in fluid level,
  • sticking of the float mechanism or delayed valve response,
  • visible wear, contamination, or damage of the component after disassembly.

HOW TO CHOOSE THE RIGHT PART

Selection of the float with valve should be unambiguous:

  • confirm that the angled version is required,
  • verify the manufacturer number: MPN 46250,
  • compare with the removed part: mounting method, connection position, and operating geometry,
  • check compatibility with the service documentation of the machine and the buffer tank.

For water-level control components, not only the valve itself matters, but also its spatial arrangement and mounting method.

COMPATIBILITY

The float with valve should be selected based on MPN 46250 and compatibility with the specific buffer tank and mounting arrangement. The angled version should not be replaced with another variant without confirming compatibility by part number and mounting geometry.

[faq]

How is the angled version different from a standard float with valve?|The difference concerns the geometry of the connection and the mounting method. The angled version is used where the tank layout or water inlet routing requires a different valve position.

Is the part number alone enough for reliable selection?|It is the best starting point, but it is also worth comparing the shape and mounting method with the removed part. In tank systems, mounting geometry is very important.

What most often causes incorrect operation of a float with valve?|Most often: water deposits, contamination, wear of the moving mechanism, or blockage of the valve by debris.

Do water-level problems always mean a damaged float?|Not always. The cause may also be valve contamination, a problem with the water supply, or incorrect positioning of the mechanism in the tank.

What should be checked after installing the new part?|After installation, it is worth checking whether the tank fills correctly, whether the valve shuts off the supply at the right moment, and whether the system works stably without overflow or water shortage.

[/faq]

Technical data

Model

Therm CA 11/130

Model

Therm CA 11/130 T

Model

Therm CA 12/150

Model

Quadro 1000 TST

Model

Therm CA 12/150 T

Model

Quadro 1200 TST

Model

Therm CA 15/120

Model

Therm C 13/180 T

Model

Quadro 799 TST

Model

Quadro 599 TST

Model

Quadro 800 TST

Model

Quadro 899 TST

Model

Therm C 11/130 T

Model

Quadro 1000 TS

Model

Quadro 1200 TS

Model

Therm C 11/130

Model

Therm C 13/180

Model

Therm C 15/150

Model

Therm C 15/150 T

Product Type

Original

Comments (0)